wiz-icon
MyQuestionIcon
MyQuestionIcon
1
You visited us 1 times! Enjoying our articles? Unlock Full Access!
Question

A Distributary is to be designed to irrigate 4000 ha in Rabi and 2500 ha in Kharif. Kor depth and Kor period for Rabi and Kharif are 16 cm, 4 weeks, and 20cm, 2 weeks respectively. Design discharge of distributary is ___(in cumec)

A
2.64
No worries! We‘ve got your back. Try BYJU‘S free classes today!
B
4.13
Right on! Give the BNAT exam to get a 100% scholarship for BYJUS courses
C
6.77
No worries! We‘ve got your back. Try BYJU‘S free classes today!
D
5.62
No worries! We‘ve got your back. Try BYJU‘S free classes today!
Open in App
Solution

The correct option is B 4.13
Rabi

Qrabi=Adwt=4000×104×16×1024×7×24×60×60=2.64Cumec

Kharif

Qkharif=A.dwt=2500×104×20×1022×7×24×60×60=4.13Cumec

Greater value = 4.13 cumec

flag
Suggest Corrections
thumbs-up
3
Join BYJU'S Learning Program
similar_icon
Related Videos
thumbnail
lock
Calculation of Design Discharge-Part-1
HYDROLOGY & IRRIGATION
Watch in App
Join BYJU'S Learning Program
CrossIcon