wiz-icon
MyQuestionIcon
MyQuestionIcon
1
You visited us 1 times! Enjoying our articles? Unlock Full Access!
Question

A 12 mm thick angle member is connected to a 16 mm thick gusset plate as a strut in a roof truss. Minimum and maximum strength of fillet weld is ensured respectively.The minimum size of fillet weld is_____ mm and maximum size of fillet weld is______ mm.

A
3 & 10.5
No worries! We‘ve got your back. Try BYJU‘S free classes today!
B
3 & 9
No worries! We‘ve got your back. Try BYJU‘S free classes today!
C
5 & 9
Right on! Give the BNAT exam to get a 100% scholarship for BYJUS courses
D
5 & 10.5
No worries! We‘ve got your back. Try BYJU‘S free classes today!
Open in App
Solution

The correct option is C 5 & 9
Minimum size of fillet weld depends on,
  • Thickness of thicker connected member {maximum of thickness of gusset plate, (16 mm) and thickness of angle section (12 mm) }is 16 mm.
Hence minimum size of fillet weld is 5 mm

Maximum size of fillet weld (for round edges) is 34 times thickness of round edge at toe.
Smax=34×12=9 mm
Hence maximum size of fillet weld is 9 mm