wiz-icon
MyQuestionIcon
MyQuestionIcon
4
You visited us 4 times! Enjoying our articles? Unlock Full Access!
Question

A 312 digit, 200 mV full scale DVM has an accuracy specification of ±0.5% of reading plus 5 counts. When the meter reads 100 mV, the voltage being measured as

A
any value between 99.5 mV and 100.5 mV
No worries! We‘ve got your back. Try BYJU‘S free classes today!
B
any value between 99.0 mV and 101.0 mV
Right on! Give the BNAT exam to get a 100% scholarship for BYJUS courses
C
exactly 99.5 mV
No worries! We‘ve got your back. Try BYJU‘S free classes today!
D
exactly 100 mV
No worries! We‘ve got your back. Try BYJU‘S free classes today!
Open in App
Solution

The correct option is B any value between 99.0 mV and 101.0 mV
Error on reading 100 mV
=100 mV×0.5100=0.5 mV

also, error due to ±5 counts

=2001999×5 mV=0.5 mV

Hence,

Total error = 0.5 + 0.5 = 1.0 mV

Meter will read between (100 - 1) mV and (100 + 1) mV.

i.e. between (99.0 mV and 101 mV).

flag
Suggest Corrections
thumbs-up
1
Join BYJU'S Learning Program
similar_icon
Related Videos
thumbnail
lock
Digital Meters, Display, Advantage
MEASUREMENT
Watch in App
Join BYJU'S Learning Program
CrossIcon