A 3-phase, 50 Hz, 16 pole generator with connected winding has 144 slots with 10 conductors per slot. The flux/pole of 24.8 mWb is sinusoidally distributed. If coil is full pitched, then line voltage is _______V.
  1. 2288.635

Open in App
Solution

The correct option is A 2288.635
Given,
Number of phases = 3
Frequency, f = 50 Hz,
No. of poles, P = 6
No. of slots = 144

Turns per phase, NP =144×102×3=240

The rms voltage per phase =4.44fϕNP

=4.44×50×24.8×103×240

=1321.344 V

Line voltage =3×1321.344

=2288.635 V