wiz-icon
MyQuestionIcon
MyQuestionIcon
17
You visited us 17 times! Enjoying our articles? Unlock Full Access!
Question

A 3-phase full wave controlled converter is fed from 3-phase 400V, 50Hz source and connected to highly inductive load with load resistance of 10Ω. If the firing angle delay is 450, the rms value of source current is ______A.
  1. 31.18

Open in App
Solution

The correct option is A 31.18
α<600

Average output voltage, V0=3VmLπcosα

=3×400×2πcos45o

V0=381.97V

I0=V0R=381.9710=38.19 A

Rms value of source current Is is,

Is=23I0=23×38.19=31.18A