CameraIcon
CameraIcon
SearchIcon
MyQuestionIcon
MyQuestionIcon
1
You visited us 1 times! Enjoying our articles? Unlock Full Access!
Question

A 3-phase fully controlled bridge converter with free wheeling diode is fed from 400 V, 50 Hz AC source and is operating at a firing angle of 60°. The load current is assumed constant at 10 A due to high load inductance. The input displacement factor (IDF) and the input power factor (IPF) of the converter will be

A

IDF = 0.5; IPF = 0.478
Right on! Give the BNAT exam to get a 100% scholarship for BYJUS courses
B

IDF = 0.867; IPF = 0.828
No worries! We‘ve got your back. Try BYJU‘S free classes today!
C

IDF = 0.867; IPF = 0.552
No worries! We‘ve got your back. Try BYJU‘S free classes today!
D

IDF = 0.5; IPF = 0.318
No worries! We‘ve got your back. Try BYJU‘S free classes today!
Open in App
Solution

The correct option is A
IDF = 0.5; IPF = 0.478
Load current is constant
I0 = 10 A

In 3ϕ full converter with free wheeling diode,
Input displacement factor (IDF)

=cosα=cos60=0.5
RMS value of source current

Is=I20×2π3×1π=I023
RMS value of nth harmonic

Ish=4I02nπsinnπ3
RMS value of fundamental current

Is1=22πI0sin60=6πI0

Current distortion factor (CDF)

=Is1Is=6πI0×(1Io32)

=3π=0.955
Input power factor (IPF)
= CDF × IDF
=0.955×0.50.478



flag
Suggest Corrections
thumbs-up
2
Join BYJU'S Learning Program
similar_icon
Related Videos
thumbnail
lock
3-Phase Full Wave Rectifiers
OTHER
Watch in App
Join BYJU'S Learning Program
CrossIcon