CameraIcon
CameraIcon
SearchIcon
MyQuestionIcon
MyQuestionIcon
188
You visited us 188 times! Enjoying our articles? Unlock Full Access!
Question

A gas is heated in a duct as it flows over a resistance heater. Consider a 101 kw electric heating system. The gas enters the heating section of the duct at 100 kPa and 270C with a volume flow rate of 15m3/s. If heat is lost from the gas in the duct to the surroundings at a rate of 51 kW, the exit temperature of the gas is (Assume constant pressure, ideal gas, negligible change in kinetic and potential energies and constant specific heat; Cp=1kJ/kgK;R=0.5kJ/kgK)

A
320C
Right on! Give the BNAT exam to get a 100% scholarship for BYJUS courses
B
370C
No worries! We‘ve got your back. Try BYJU‘S free classes today!
C
760C
No worries! We‘ve got your back. Try BYJU‘S free classes today!
D
530C
No worries! We‘ve got your back. Try BYJU‘S free classes today!
Open in App
Solution

The correct option is A 320C

Since it is given an ideal gas
and. cp=1kJ/kgK
R=0.5kJ/kgK

at inlet P1˙V1=˙mRT1
˙m=P1˙V1RT1=100×150.5×300=10kg/s

Using SFEE
˙mh1+Q=˙mh2+W
h1+Q˙m=h2+W˙m
cpT1[5110]=cpT210110
(T2T1)cp=1015110=5
T2T1=5cp=5k
T2=300+5=305kor320C


flag
Suggest Corrections
thumbs-up
0
similar_icon
Similar questions
View More
Join BYJU'S Learning Program
similar_icon
Related Videos
thumbnail
lock
Heat Capacity
CHEMISTRY
Watch in App
Join BYJU'S Learning Program
CrossIcon