wiz-icon
MyQuestionIcon
MyQuestionIcon
9
You visited us 9 times! Enjoying our articles? Unlock Full Access!
Question

A generator supplied power to a factory through cables of total resistance 20Ω. The potential difference at the generator is 5kV and the power output is 50kW. The potential difference of the supply mains at the factory is-

A
5kV
No worries! We‘ve got your back. Try BYJU‘S free classes today!
B
4.4kV
No worries! We‘ve got your back. Try BYJU‘S free classes today!
C
4.8kV
Right on! Give the BNAT exam to get a 100% scholarship for BYJUS courses
D
4.6kV
No worries! We‘ve got your back. Try BYJU‘S free classes today!
Open in App
Solution

The correct option is D 4.8kV

Current through cable I=PV=50kW5kV=10A


Potential drop across th ecables =IR=(10)(20)=200V


So potential difference at factory =5000200=4800V


flag
Suggest Corrections
thumbs-up
0
Join BYJU'S Learning Program
similar_icon
Related Videos
thumbnail
lock
Power Transmission
PHYSICS
Watch in App
Join BYJU'S Learning Program
CrossIcon