A plant with a transfer function 2s(s+3) is controlled by a PI controller with Kp=1 and ki≥0 in a unity feedback configuaration.The lowest value of Ki that ensures zero steady state error for a step change in the referance input is
A
0
Right on! Give the BNAT exam to get a 100% scholarship for BYJUS courses
B
1/3
No worries! We‘ve got your back. Try BYJU‘S free classes today!
C
1/2
No worries! We‘ve got your back. Try BYJU‘S free classes today!
D
1
No worries! We‘ve got your back. Try BYJU‘S free classes today!
Open in App
Solution
The correct option is A 0 Given, Kp=1, transfer function for PI controller is T(s)=Kp(1+1Kis)=Kis+1Kis
Open loop transfer function G(s)=Kis+1Kis×2s(s+3)=2(Kis+1)Kis2(s+3)
therefore characteristic equation is 1+G(s)=0 Kis3+Kis2+2Kis+2=0
Routh array will be
for system to be stable Ki>0
and 2 Ki−2/3>0 ⇒Ki>0andKi>1/3 ⇒Ki>1/3
Now Kp→ position error constant =lims→0G(s)=∞ ∴ess=11+Kp=0
So it is independent of Ki