CameraIcon
CameraIcon
SearchIcon
MyQuestionIcon
MyQuestionIcon
3
You visited us 3 times! Enjoying our articles? Unlock Full Access!
Question

A PWM with unipolar switching scheme is used in an inverter, with fundamental frequency = 49 Hz and Mf=38. Which of the following harmonic frequency is present in the output ?

Open in App
Solution

In unipolar switching,
Harmonic order, h=j(2mf)±k
h=j76±k
fH=(j76±k)×49
j=1,k=1
fH=3675 Hz, 3773 Hz

flag