CameraIcon
CameraIcon
SearchIcon
MyQuestionIcon
MyQuestionIcon
1
You visited us 1 times! Enjoying our articles? Unlock Full Access!
Question

A T-beam of flange width 1200mm, flange thickness 100 mm, rib width 275 mm has an effective depth of 550 mm and is reinforced with 6 bars of 25 mmϕ. The ultimate MOR will be ____ kNm. [Use M30 concrete and Fe415 steel]
  1. 548.21

Open in App
Solution

The correct option is A 548.21
Ast=6×π4(25)2=2945.24mm2

xu,lim=0.48×550=264mm

Assume neutral axis in flange.

xu=0.87×415×2945.240.36×30×1200=82.05mm<Df(=100mm)

MOR=0.87fAst(d0.42xu)

=0.87×415×2945.24×(5500.42×82.05)

=548.21×106N-mm = 548.21 kN-m

flag
Suggest Corrections
thumbs-up
3
similar_icon
Similar questions
View More
Join BYJU'S Learning Program
similar_icon
Related Videos
thumbnail
lock
Curved Surface Area of a Cylinder
MATHEMATICS
Watch in App
Join BYJU'S Learning Program
CrossIcon