wiz-icon
MyQuestionIcon
MyQuestionIcon
1
You visited us 1 times! Enjoying our articles? Unlock Full Access!
Question

A transmission line of real characteristic impedance is terminated with an unknown load. The measured value of VSWR on the line is equal to 2 and a voltage minimum point is found to be at the load. The load impedance is then

Open in App
Solution

Ans : (c)

Given, voltage minimum (vmin) point is at load.

If vmin or vmax occurs at the load for a lossless transmission line then load impedance ZL is purely resistive.

If ZL (resistive) > Z0, voltage maxima occurs at the load.

If ZL (resisitive) < Z0, voltage minima occurs at the load.

flag
Suggest Corrections
thumbs-up
0
Join BYJU'S Learning Program
similar_icon
Related Videos
thumbnail
lock
Reflection Coefficient for Complex Load
OTHER
Watch in App
Join BYJU'S Learning Program
CrossIcon