A two stage single acting air compressor delivers, 1000 kg/hr of air at 20 bar pressure. The suction occurs at STP conditions . Assume the process to be ideal; the free air delivery is _____ m3/min
12.89
Open in App
Solution
The correct option is A 12.89
m=1000kg/hr
R=0.287kJ/kgK=287J/kgK
STP conditions
P=101.325kPa
T=273.15K
∴Free air delivery,V=mRTP=1000×387⊓273.15101.32×103=773.72m3/hr=12.89m3/min