An industrial heat pump operates between the temperatures of 27C and 13C. The rates of heat addition and heat rejection are 750 W and 1000 W, respectively. The COP for the heat pump is

A
7.5
No worries! We‘ve got your back. Try BYJU‘S free classes today!
B
6.5
No worries! We‘ve got your back. Try BYJU‘S free classes today!
C
4.0
Right on! Give the BNAT exam to get a 100% scholarship for BYJUS courses
D
3.0
No worries! We‘ve got your back. Try BYJU‘S free classes today!
Open in App
Solution

The correct option is C 4.0
Given data:

T1=27C=(27+273)K=300K

T2=13C=(13+273)K=260K

Q2=750W

Q1=1000W



(COP)HP=Q1Q1Q2 for actual heat pump

=10001000750=1000250=4