An outlet irrigates an area of 20 ha. Discharge (L/s) required at this outlet to meet the evapotranspiration requirement of 20 mm occurring uniformly in 20 days neglecting other field losses

A
2.52
No worries! We‘ve got your back. Try BYJU‘S free classes today!
B
2.31
Right on! Give the BNAT exam to get a 100% scholarship for BYJUS courses
C
2.01
No worries! We‘ve got your back. Try BYJU‘S free classes today!
D
1.52
No worries! We‘ve got your back. Try BYJU‘S free classes today!
Open in App
Solution

The correct option is B 2.31
The volume of water required for evapotranspiration
= Area × depth

=(20×104)(20×103)

=4000 m3

V=4×106 l

This volume has to be supplied in 20 days
Discharge=Vt=4×10620×86400

=2.315 l/s