Question

Dead Load = 200 kN
Live Load = 300 kN
Wind Load = 120 kN
Earthquake Load = 180 kN
The Design Load (kN) as per limit state of serviceability is

A
750
No worries! We‘ve got your back. Try BYJU‘S free classes today!
B
500
No worries! We‘ve got your back. Try BYJU‘S free classes today!
C
816
No worries! We‘ve got your back. Try BYJU‘S free classes today!
D
584
Right on! Give the BNAT exam to get a 100% scholarship for BYJUS courses
Open in App
Solution

The correct option is D 584
Limit state of serviceability

( DL+ max ( LL+ WL +EL ))

200 + max ( 300, 120, 180 )

= 500 kN

DL + 0.8 LL + 0.8 max (WL, EL)

=200+0.8×300+0.8(180)

=584 kN

Design load = 584 kN