For a culturable command area of 1000 hectares with the intensity of irrigation of 50%, the duty on the field for a certain crop is 2000 hectares/cumec. What is the discharge required at the head of the watercourse with 25% losses of water?
A
3/16 cumec
No worries! We‘ve got your back. Try BYJU‘S free classes today!
B
1/4 cumec
No worries! We‘ve got your back. Try BYJU‘S free classes today!
C
1/3 cumec
Right on! Give the BNAT exam to get a 100% scholarship for BYJUS courses
D
1/2 cumec
No worries! We‘ve got your back. Try BYJU‘S free classes today!
Open in App
Solution
The correct option is C 1/3 cumec The area to be irrigated =0.5×100=500ha
The discharge needed on the field
=5002000=0.25cumec
For 25% loss of water at the head of water course, the discharge required at the head of water course