If the loading on a simply supported prestressed concrete beam is uniformly distributed, the centroid of the prestressing tendon should be as
A
A straight profile along the lower edge of the kern
No worries! We‘ve got your back. Try BYJU‘S free classes today!
B
A parabolic profile with convexity downward
Right on! Give the BNAT exam to get a 100% scholarship for BYJUS courses
C
A straight profile along the centroidal axis
No worries! We‘ve got your back. Try BYJU‘S free classes today!
D
A circular profile with convexity upward
No worries! We‘ve got your back. Try BYJU‘S free classes today!
Open in App
Solution
The correct option is B A parabolic profile with convexity downward For simply supported beam subjected to UDL, BMD is parabolic. For load balancing shape of cable shall be as per same profile (parabolic) with convexity downward.