wiz-icon
MyQuestionIcon
MyQuestionIcon
1
You visited us 1 times! Enjoying our articles? Unlock Full Access!
Question

In a point to point control NC machine, the slides positioned by an integrally mounted motor drive. If the specification of the motor is 1 deg/ pulse, and the pitch of the lead screw is 3.6 mm. What is the expected positioning accuracy?

A
100 micron
No worries! We‘ve got your back. Try BYJU‘S free classes today!
B
1 micron
No worries! We‘ve got your back. Try BYJU‘S free classes today!
C
10 micron
Right on! Give the BNAT exam to get a 100% scholarship for BYJUS courses
D
50 micron
No worries! We‘ve got your back. Try BYJU‘S free classes today!
Open in App
Solution

The correct option is C 10 micron
For 1 rev. of lead screw slide will move by 3.6 mm
1 rev. =360=360 pulses
360 pulses will cause motion of 3.6 mm
1 pulse will result in 3.6360mmof motion
i.e.. 0.01mmor10μm