In the case of a P.S.C. beam, to satisfy the Limit State of Serviceability in cracking, match List-I with List-II and select the correct answer using the codes given below the lists:

List - I
A. Class 1 structure
B. Class 2 structure
C. Class 3 structure
List- II
1. No visible cracking σ1<3 N/mm2
2. Concrete section uncracked; crack width to be calculated to check
3. No cracking under service loads
Codes:A B C

A
1 2 3
No worries! We‘ve got your back. Try BYJU‘S free classes today!
B
2 1 3
No worries! We‘ve got your back. Try BYJU‘S free classes today!
C
3 1 2
Right on! Give the BNAT exam to get a 100% scholarship for BYJUS courses
D
3 2 1
No worries! We‘ve got your back. Try BYJU‘S free classes today!
Open in App
Solution

The correct option is C 3 1 2
IS1343: 1980 (clause 19.3.2) gives serviceability limit states.
Class 1 structures-no cracking under service loads
Class 2 structures-no visible cracking when σ<3 N/mm2
Class 3 structures -concrete section uncracked