In the context of low resistances, identify the INCORRECT statement
A
standard low resistances have four terminal construction.
No worries! We‘ve got your back. Try BYJU‘S free classes today!
B
Kelvin bridge is used for measuring low resistance, precision depends on the detector sensitivity.
No worries! We‘ve got your back. Try BYJU‘S free classes today!
C
A pair of ratio arms in Kelvin bridge for measuring the low resistance eliminates the error due to thermo emf.
Right on! Give the BNAT exam to get a 100% scholarship for BYJUS courses
D
low resistances used for ammeter shunts are usually made with a suitable number of plates of large area and all the plates connected in parallel.
No worries! We‘ve got your back. Try BYJU‘S free classes today!
Open in App
Solution
The correct option is C A pair of ratio arms in Kelvin bridge for measuring the low resistance eliminates the error due to thermo emf. (i) Low resistance has four terminals to remove effect of lead resistance.
(ii) Kelvin double bridge is used to measure low resistance whose precision depends on the detector sensitivity.
(iii) Pair of ratio arms in Kelvin bridge for measuring the low resistance eliminates error due to lead resistance.
Note:
Low resistance → Four terminal to remove effect to lead resistance
Medium resistance → Two terminals
High resistance → Three terminals to remove insulation resistance.