In using the data from a plate bearing test for deterring the modulus of sub-grade reaction, the value of settlement (mm) to be used is
A
3.75
No worries! We‘ve got your back. Try BYJU‘S free classes today!
B
2.50
No worries! We‘ve got your back. Try BYJU‘S free classes today!
C
1.25
Right on! Give the BNAT exam to get a 100% scholarship for BYJUS courses
D
1.75
No worries! We‘ve got your back. Try BYJU‘S free classes today!
Open in App
Solution
The correct option is C 1.25 Modulus of subgrade reaction is based on settlement of 0.125 cm
Note : Modulus of subgrade reaction K may be defined as the pressure sustained per unit deformation of the subgrade at specified deformation or pressure level, using specified plate size. The standard plate size for finding K-value is 75 cm dia. But in some tests a smaller plate of 30 cm dia. is also used.