Q14. With reference to the Standards for Treatment and Disposal of Biomedical Waste, consider the following statements.
1.
Chlorinated plastics shall be incinerated.
2. The autoclave should be dedicated for the purposes of disinfecting and treating bio-medical waste.
3. Microwave treatment shall be used for cytotoxic, hazardous or radioactive wastes, contaminated animal carcasses, body parts and large metal items.
Select the correct answer using the codes given.


A
(a) Only 1 and 2
No worries! We‘ve got your back. Try BYJU‘S free classes today!
B
(b) Only 2
Right on! Give the BNAT exam to get a 100% scholarship for BYJUS courses
C
(c) Only 3
No worries! We‘ve got your back. Try BYJU‘S free classes today!
D
(d) All of the above
No worries! We‘ve got your back. Try BYJU‘S free classes today!
Open in App
Solution

The correct option is B (b) Only 2

I.STANDARDS FOR INCINERATORS:
1.
Suitably designed pollution control devices should be installed/retrofitted with the incinerator to achieve the above emission limits, if necessary.
2. Wastes to be incinerated shall not be chemically treated with any chlorinated disinfectants.
3. Chlorinated plastics shall not be incinerated.Toxic metals in incineration ash shall be limited within the regulatory quantities as defined under the Hazardous Waste (Management and Handling Rules,) 1989.
STANDARDS FOR WASTE AUTOCLAVING:
The autoclave should be dedicated for the purposes of disinfecting and treating bio-medical waste,
When operating a gravity flow autoclave, medical waste shall be subjected to :
1. a temperature of not less than 121 C° and pressure of 15 pounds per square inch (psi) for an autoclave residence time of not less than 60 minutes; or
2. a temperature of not less than 135 C° and a pressure of 31 psi for an autoclave residence time of not less than 45 minutes; or
3. a temperature of not less than 149 C° and a pressure of 52 psi for an autoclave residence time of not less than 30 minutes.
STANDARDS FOR MICROWAVING:
1.
Microwave treatment shall not be used for cytotoxic, hazardous or radioactive wastes, contaminated animal car casses, body parts and large metal items.
2. The microwave system shall comply with the efficacy test/routine tests and a performance guarantee may be provided by the supplier before operation of the limit.
3. The microwave should completely and consistently kill the bacteria and other pathogenic organisms that is ensured by approved biological indicator at the maximum design capacity of each microwave unit. Biological indicators for microwave shall be Bacillus Subtilis spores using vials or spore strips with at least 1 x 101 spores per milliliter.