Question

The input impedance of the permanent magnet moving coil (PMMC) voltmeter is infinite. Assuming that the diode shown in the figure below is ideal, the reading of the voltmeter in Volts is


A
4.46
Right on! Give the BNAT exam to get a 100% scholarship for BYJUS courses
B
3.15
No worries! We‘ve got your back. Try BYJU‘S free classes today!
C
2.23
No worries! We‘ve got your back. Try BYJU‘S free classes today!
D
0
No worries! We‘ve got your back. Try BYJU‘S free classes today!
Open in App
Solution

The correct option is A 4.46
In the positive half cycle, D is ON
V0=0V
In negative half cycle, D is OFF, PMMC voltmeter mesasures average value of V0.
In case of half wave rectification,
V0avg.=14.14π×100101
=4.456V