CameraIcon
CameraIcon
SearchIcon
MyQuestionIcon
MyQuestionIcon
1
You visited us 1 times! Enjoying our articles? Unlock Full Access!
Question

The length of bolts joint made from 16 mm bolts is 300 mm. The reduction factor used for calculation of shear strength of bolts is

A
0.929
No worries! We‘ve got your back. Try BYJU‘S free classes today!
B
0.967
No worries! We‘ve got your back. Try BYJU‘S free classes today!
C
0.981
Right on! Give the BNAT exam to get a 100% scholarship for BYJUS courses
D
No reduction factor for given data
No worries! We‘ve got your back. Try BYJU‘S free classes today!
Open in App
Solution

The correct option is C 0.981
Length of joint, lj=300mm>15d(15×16=240mm)
Reduction factor, βij<1.075lj200d
=1.075300200×16=0.981

flag
Suggest Corrections
thumbs-up
0
Join BYJU'S Learning Program
similar_icon
Related Videos
thumbnail
lock
Fluids Pressure and Density
PHYSICS
Watch in App
Join BYJU'S Learning Program
CrossIcon