Question

The length of bolts joint made from 16 mm bolts is 300 mm. The reduction factor used for calculation of shear strength of bolts is

A
0.929
No worries! We‘ve got your back. Try BYJU‘S free classes today!
B
0.967
No worries! We‘ve got your back. Try BYJU‘S free classes today!
C
0.981
Right on! Give the BNAT exam to get a 100% scholarship for BYJUS courses
D
No reduction factor for given data
No worries! We‘ve got your back. Try BYJU‘S free classes today!
Open in App
Solution

The correct option is C 0.981
Length of joint, lj=300mm>15d(15×16=240mm)
Reduction factor, βij<1.075lj200d
=1.075300200×16=0.981