The line reactance of a power system network are as follows:
From Bus
To Bus
Reactance
0
1
0.3 p.u.
1
2
0.5 p.u
The bus impedance matrix with '0' as reference bus is,
A
[
0.3
0.6
0.6
0.8
]
No worries! We‘ve got your back. Try BYJU‘S free classes today!
B
[
0.5
0.3
0.3
0.8
]
No worries! We‘ve got your back. Try BYJU‘S free classes today!
C
[
0.3
0.3
0.6
0.8
]
No worries! We‘ve got your back. Try BYJU‘S free classes today!
D
[
0.3
0.3
0.3
0.8
]
Right on! Give the BNAT exam to get a 100% scholarship for BYJUS courses
Open in App
Solution
The correct option is
D
[
0.3
0.3
0.3
0.8
]
Z
B
u
s
(
n
e
w
)
=
[
0.3
0.3
0.3
0.3
+
0.5
]
=
[
0.3
0.3
0.3
0.8
]
Suggest Corrections
0
Similar questions
Q.
A new generator having
E
g
=
1.4
∠
30
∘
pu
[equivalent to (1.212+j 0.70)pu] and synchronous reactance
′
X
′
s
of 1.0 pu on the system base, is to be connected to a bus having voltage V, in the existing power system. This existing power system can be represented by Thevenin's voltage
E
t
h
=
0.9
∠
0
∘
pu in series with Thevenin's impedance
Z
t
h
=
0.25
∠
90
∘
pu. The magnitude of the bus voltage
V
t
of the system in pu will be
Q.
Consider the network shown. Bus numbers and impedances are marked. An element having an impedance of
0.8
Ω
is connected between bus 2 and reference bus.
Z
22
n
e
w
becomes ___pu.
Q.
A 3-bus power system is shown in the figure below, where the diagonal elements of Y-bus matrix are:
Y
11
=
−
j
12
p
u
,
Y
22
=
−
j
15
p
u
a
n
d
Y
33
=
−
j
7
p
u
.
The per unit values of the line reactances p,q and r shown in the figure are
Q.
A lossless transmission line with 0.3 pu reactance per phase uniformly distributed along the length of line, connecting a generator bus to a load bus, is protected upto 85% of its length by a distance relay placed at the generator bus. The generator terminal voltage is 1 pu. If no generator is at the load bus, the threshold pu current for operation of distance relay for a solid three phase to ground fault on the transmission line will be________ (upto 2 decimal places)
Q.
A two bus system is as shown below,
Corresponding Z-bus matrix is
Z
=
[
j
0.5
j
0.5
j
0.5
j
4.5
]
If the line between bus 1 and bus 2 is replaced with another line having reactance
(
j
2
)
Ω
, then modified
Z
b
u
s
is
View More
Join BYJU'S Learning Program
Grade/Exam
1st Grade
2nd Grade
3rd Grade
4th Grade
5th Grade
6th grade
7th grade
8th Grade
9th Grade
10th Grade
11th Grade
12th Grade
Submit
Related Videos
Z-Bus Building Algorithm
POWER SYSTEMS
Watch in App
Explore more
Z-Bus Building Algorithm
Other Power Systems
Join BYJU'S Learning Program
Grade/Exam
1st Grade
2nd Grade
3rd Grade
4th Grade
5th Grade
6th grade
7th grade
8th Grade
9th Grade
10th Grade
11th Grade
12th Grade
Submit
AI Tutor
Textbooks
Question Papers
Install app