The PMMC ammeter A in the adjoining figure has a range of 0 to 3 mA. When switch S1 is opened, the pointer of the ammeter swings to the 1 mA mark, returns and settles at 0.9 mA. The meter is
A
critically damped and has a coil resistance of 100Ω
No worries! We‘ve got your back. Try BYJU‘S free classes today!
B
Critically damped and has a coil resistance of 200Ω
No worries! We‘ve got your back. Try BYJU‘S free classes today!
C
under damped and has a coil resistance of 100Ω
No worries! We‘ve got your back. Try BYJU‘S free classes today!
D
under damped and has a coil resistance of 200Ω
Right on! Give the BNAT exam to get a 100% scholarship for BYJUS courses
Open in App
Solution
The correct option is D under damped and has a coil resistance of 200Ω Current through the PMMC ammeter is noted as 0.9 mA.
0.9×10−3=1.8(1.8×103+R3)
Ra= ammeter resistance
(0.9×10−3)(1.8×103+Ra)=1.8
0.9×1.8+0.9×10−3Ra=1.8
0.9×10−3Ra=1.8−0.9×1.8
0.9×10−3Ra=1.8×0.1
∴Ra=200Ω
Since, the points of the ammeter first swings around 1 mA and then settles at 0.9 mA, hence the ammeter is under-damped.