The slope and level detector circuit in a CRO has a delay of 100 ns. The start-stop sweep generator has a response time of 50 ns. In order to display correctly, a delay line of
A
150 ns has to be inserted into the y-channel.
Right on! Give the BNAT exam to get a 100% scholarship for BYJUS courses
B
150 ns has to be inserted into the x-channel.
No worries! We‘ve got your back. Try BYJU‘S free classes today!
C
150 ns has to be inserted into both x and y channels.
No worries! We‘ve got your back. Try BYJU‘S free classes today!
D
100 ns has to be inserted into both x and y channels.
No worries! We‘ve got your back. Try BYJU‘S free classes today!
Open in App
Solution
The correct option is A 150 ns has to be inserted into the y-channel. A delay line of 150 ns has to be inserted into the y-channel to get synchronous between sweep signal applied to x-plate and test signal applied to y-plate.