The turn ratio of a transformer is given as 2:3. If the current through the primary coil is 3 A, then calculate the current through load resistance.
2 A
Consider,
V1: Voltage across the primary coil
V2: voltage across the secondary coil
N1 : Number of turns in primary coil
N2: Number of turns in secondary coil
So, the relation between these terms:-
V1N1 = V2N2
The turn ratio of the transformer is :-
N1N2=V1V2
We have known that,
V1I1 = V2I2⇒V1V2=I2I1
So,I2I1=N1N2
⇒I23=23
⇒I2 = 2 A