Question

Two channel sections are connected by a single lacing system as shown in figure. The minimum thickness of lacing flat (Nearest integer) will be _____ mm.
(Assume lacing angle as 45)


Open in App
Solution

Length of lacing=283.5× cosec45
=400.9295 mm

Minimum thickness of lacing flat for single lacing system =
l40
=400.92940=10.02=11 mm

( 10.02 mm is minimum required thickness , practically we should choose 12 but here in numerical we can take 11 mm )