CameraIcon
CameraIcon
SearchIcon
MyQuestionIcon
MyQuestionIcon
1
You visited us 1 times! Enjoying our articles? Unlock Full Access!
Question

Two ISMC 400 channels are placed back to back at a spacing of 250 mm to carry an axial load of 800 kN.The lacing system should be designed to resist a transverse shear of_____________kN.

Open in App
Solution

The lacing system is designed for a load which is 2.5% of the axial load i.e
Pdesign=2.5100×800=20kN

flag
Suggest Corrections
thumbs-up
0
Join BYJU'S Learning Program
similar_icon
Related Videos
thumbnail
lock
Built Up Columns - Lacing
OTHER
Watch in App
Join BYJU'S Learning Program
CrossIcon