Two ISMC 400 channels are placed back to back at a spacing of 250 mm to carry an axial load of 800 kN.The lacing system should be designed to resist a transverse shear of_____________kN.

Open in App
Solution

The lacing system is designed for a load which is 2.5% of the axial load i.e
Pdesign=2.5100×800=20kN