CameraIcon
CameraIcon
SearchIcon
MyQuestionIcon
MyQuestionIcon
1
You visited us 1 times! Enjoying our articles? Unlock Full Access!
Question

Two plates of 8 mm thickness each are connected by a fillet weld of 6 mm thickness as shown in the figure.


The permissible stresses in the plate and the weld are 150 MPa and 110 MPa respectively. Assuming the length of the weld shown in the figure to be the effective length the permissible load P (in kN) is ____.
  1. 60

Open in App
Solution

The correct option is A 60
Maximum load taken by plate

=150×50×8=60 kN

Maximum load taken by the weld

= KS Leff σs

=0.7×6×(100+50+100)×110=115.5 kN

Permissible load = minimum of above two
=60 kN

flag
Suggest Corrections
thumbs-up
0
Join BYJU'S Learning Program
similar_icon
Related Videos
thumbnail
lock
Design Strength of Fillet Weld
OTHER
Watch in App
Join BYJU'S Learning Program
CrossIcon