Question

Two plates of 8 mm thickness each are connected by a fillet weld of 6 mm thickness as shown in the figure.


The permissible stresses in the plate and the weld are 150 MPa and 110 MPa respectively. Assuming the length of the weld shown in the figure to be the effective length the permissible load P (in kN) is ____.
  1. 60

Open in App
Solution

The correct option is A 60
Maximum load taken by plate

=150×50×8=60 kN

Maximum load taken by the weld

= KS Leff σs

=0.7×6×(100+50+100)×110=115.5 kN

Permissible load = minimum of above two
=60 kN