wiz-icon
MyQuestionIcon
MyQuestionIcon
1
You visited us 1 times! Enjoying our articles? Unlock Full Access!
Question

Two plates of thickness 14 mm and 12 mm are to be joined by single V groove weld joint. Assuming an effective length of 150 mm. Fe 410 grade steel plates are used and the welds are shop welded. The maximum factored tensile force the joint can subject is______.
fy=250N/mm2.

Open in App
Solution

In case single V groove weld

Throat thickness te=58t=58×12=7.5 mm

Effective length of weld =
Lw=150 mm

Strength of weld
=Lwtefyγmw

=7.5×150×2501.25=225 kN

Maximum factored tensile force = 225 kN

flag
Suggest Corrections
thumbs-up
1
similar_icon
Similar questions
View More
Join BYJU'S Learning Program
similar_icon
Related Videos
thumbnail
lock
Design Strength of Butt Weld
OTHER
Watch in App
Join BYJU'S Learning Program
CrossIcon