Two plates of thickness 14 mm and 16 mm are to be joined by a double - V groove weld. The effective length of joint is 160 mm. The strength of weld is ________ kN. Assume that Fe410 grade steel plates are used and that the welds are shop welded.

Open in App
Solution

In the case of double - V groove weld, complete penetration takes place

Throat thickness = Thickness of thinner plate
=14 mm

Strength of weld
=t×leff×fyγmw

=14×160×2501.25×1000kN=448 kN(γmw=1.25 for shop welding)