Question

When new, a heat exchanger transfers 10% more heat than it does after being in service for six months. Assuming that it operates between the same temperature differentials and that there is insufficient scale built up to change the effective surface area. The fouling factor of heat exchanger if the overall heat transfer coefficient is 200W/m2K is

A
0.05K/W
No worries! We‘ve got your back. Try BYJU‘S free classes today!
B
0.005K/W
No worries! We‘ve got your back. Try BYJU‘S free classes today!
C
0.0005K/W
Right on! Give the BNAT exam to get a 100% scholarship for BYJUS courses
D
0.5K/W
No worries! We‘ve got your back. Try BYJU‘S free classes today!
Open in App
Solution

The correct option is C 0.0005K/W
QnQ0=UnAn(ΔT)nU0A0(ΔT)0

Since An=A0, (ΔT)n=(ΔT)0

And Qn=1.1Q0

1.1=UnU0

U0=Un1.1=2001.1=181.82

Fouling factor

F=1U01Un

=1181.821200=0.0005kW