A bridge circuit consist ot two fixed resistance and two strain gauges of each value of 100Ω. If the gauge factor of 2 & the strain of 200μ strain. If the supplied battery current of 100mA. Then the sensitivity in volt per unit strain is
10
Open in App
Solution
The correct option is A 10
Supplied voltage ei=100×10−3×100=10V
Output voltage eo=Gfεei2=2×200×10−6×102
e0=2mV
Sensitivity of the bridge (Vstrain)=2×10−3200×10−6