A copper constantan thermocouple temperature measurement data with respect 0oC as
Temperature 30 60 70 ... 200 220 230
Voltage (mV) 0.5 0.75 0.93 ... 9.7 10.2 11.0

The copper constantan thermcouple is connected to a potentiometer whose terminals are at 30oC, the potentiometer reads 9.7 mV then the open circuit temperature of the thermocouple at 0oC is
  1. 220

Open in App
Solution

The correct option is A 220
E002200C=E00300C+E3002200C

=0.5 mV+9. mV

=10.2 mV

Corresponding temperature to 10.2 mV is 220oC.