A screw gauge with a pitch of 0.5 mm and a circular scale with 50 divisions is used to measure the thickness of a thin sheet of Aluminium. Before starting the measurement, it is found that when the two jaws of the screw gauge are brought in contact, the 45th division coincides with the main scale line and that the zero of the main scale is barely visible. What is the thickness of the sheet if the main scale reading is 0.5 mm and the 25th division coincides with the main scale line?

A
0.50 mm
No worries! We‘ve got your back. Try BYJU‘S free classes today!
B
0.75 mm
No worries! We‘ve got your back. Try BYJU‘S free classes today!
C
0.80 mm
Right on! Give the BNAT exam to get a 100% scholarship for BYJUS courses
D
0.70 mm
No worries! We‘ve got your back. Try BYJU‘S free classes today!
Open in App
Solution

The correct option is C 0.80 mm
Reading =MSR+CSR Zero error

LC=pitchno. of divisions=0.5 mm50LC=0.01 mm

Zero error is negative as it is lagging 5 divisions before coinciding with main scale.
Zero error =5×LC=5×0.01=0.05 mm

MSR=0.5 mm
As 25th division is coinciding,
CSR=0.5/2=0.25 mm

Reading =0.5+0.25(0.05)=0.80 mm