Question

A simply supported beam has an effective span of 16 m. What shall be the limiting ratio of span to effective depth as per IS 456- 2000?

A
26
No worries! We‘ve got your back. Try BYJU‘S free classes today!
B
20
No worries! We‘ve got your back. Try BYJU‘S free classes today!
C
12.5
Right on! Give the BNAT exam to get a 100% scholarship for BYJUS courses
D
7
No worries! We‘ve got your back. Try BYJU‘S free classes today!
Open in App
Solution

The correct option is C 12.5
(c) According to clause 23.2.1
For a simply supported beam value of span to effective depth

LD=20

For span above 10 m, the value given above shall be multiplied by 10/span in metres i.e.,

1016=0.625

Ld=20×0.625=12.5