The discharge capacity required at the outlet to irrigate 2600 ha of sugarcane having a kor depth of 17 cm and a kor period of 30 days is

A
2.3 m3/s
No worries! We‘ve got your back. Try BYJU‘S free classes today!
B
1.71 m3/s
Right on! Give the BNAT exam to get a 100% scholarship for BYJUS courses
C
14.7 m3/s
No worries! We‘ve got your back. Try BYJU‘S free classes today!
D
0.18 m3/s
No worries! We‘ve got your back. Try BYJU‘S free classes today!
Open in App
Solution

The correct option is B 1.71 m3/s
Given: Area = A = 2600 ha
Kor depth =Δ=17 cm =0.17 m
Kor period=B=30 days
Discharge capacity required at the outlet to irrigation =
Q=A×ΔB×86400=2600×104×0.1730×86400
=1.71 m3/sec.
Note:
1. Kor watering:
The first watering after the plants have grown a few centimetre high is known as kor watering.
2. Kor depth: The depth of water applied during this watering is called kor depth.
3. Kor period: The kor watering must be done in a limited period which is known as kor period.